ISO 13849-1 Advanced Course

Performance Level d (PL d)

Standard of Industrial Safety,

Why do robots and automation systems require PL d?
Learn the design know-how to reduce the probability of dangerous failure to 1 in 10 million.

Module 1. Definition and Meaning of PL d

How safe must it be to be PL d?

Probability of Dangerous Failure per Hour (PFHd)

The PL grade is not just saying "it's safe".
It quantifies the "probability of a dangerous failure occurring during 1 hour of operation".

PLPFHd (1/h)Reliability Level
PL c≥ 10-6 ~ < 3 × 10-61 in a Million
PL d≥ 10-7 ~ < 10-61 in 10 Million
PL e≥ 10-8 ~ < 10-71 in 100 Million

Why is PL d for Robots?

  • S2Serious Injury (Severity)
    Possibility of fracture, amputation, or death upon collision.
  • F2Frequent Exposure (Frequency)
    Operators frequently approach the robot in automation lines.
  • P1Possibility of Avoidance
    Can be avoided under specific conditions (e.g., slow speed).

Risk Assessment Result ⇒ Minimum PL d Required

Module 2. Recipe to Achieve PL d

The standard design combination to achieve PL d

The Golden Formula for PL d Most common "Category 3" based configuration

  1. 1

    Category 3 Redundancy

    Architectural Requirements
    No loss of safety function even with a single fault

  2. 2

    MTTFd Medium ~ High

    Component Reliability
    Use certified components with low failure rates (Check B10d)

  3. 3

    DCavg Low ~ Medium

    Diagnostic Coverage
    Cross-check (Feedback) of I/O status

Note: While theoretically Category 2 (Single channel + Test) can achieve PL d, Category 3 (Redundancy) is the industrial standard for robot systems due to control complexity and test cycle limitations.

Module 3. Practical Circuit Design (Category 3)

Example of perfect redundancy from input to output

  1. INPUTE-Stop Button
    • NC 1
    • NC 2

    ★ 2 Contacts (Redundancy)

  2. LOGICSafety PLC / Relay
    • Channel A Processing
    • Channel B Processing

    Cross Monitoring

  3. OUTPUTPower Cut-off (MC)
    • MC 1
    • MC 2

    ★ Series Connection

EDM (External Device Monitoring) Feedback Loop

Common Mistakes (Failure Causes)

  • Single Contact: Connecting E-Stop with only 1 contact (Cat 1 or lower).
  • Standard PLC: Handling Safety Functions with standard PLC logic (No diagnostics).
  • Fault Masking: Simple series connection of multiple E-Stop buttons prevents fault detection.

Success Points (Check Point)

  • EDM Mandatory: Feedback of the output MC's auxiliary contact (NC) to the safety controller.
  • CCF Consideration: Separate cabling or shielding to prevent common cause failures.

Module 4. Verification & Software

Manual PL calculation is prone to errors. Verification software is used in the industrial field.

PAScal

Safety calculation software by Pilz

SISTEMA

Free standard tool by IFA (Widely used)

Education Material
Based on EN ISO 13849-1:2015